Customer Reviews for VEVOR VFD 10HP, 7.5KW, 34A, 1 Phase 220V-240V Input to 3 Phase 220V-240V Output Variable Frequency Drive, 0-400Hz VFD for AC Motor Speed Control
10 HP
Customer Reviews
How customer reviews and ratings work
Customer Reviews, including Product Star Ratings help customers to learn more about the product and decide whether it is the right product for them.
Our overall rating is not a simple average. We prioritize authentic, trustworthy reviews and filter out duplicates or invalid content before calculating the final score. This helps ensure the rating truly reflects real customer experiences.
Review this product
Share your thoughts with other customers
Write a Review
83 Reviews
Reviews for Current Item
Verified Purchase
Photos and video only
Translate all reviews to English
Machinist
10 HP
Used this to power my cnc mill and it works perfectly.
0 people found this helpful
Aide svp
10 HP
Est ce que quelq'un peut m aider a le programmer pour un pont triphasé svp
Zéro six ciquente neuf zéro six rero un ciquente quatre,merci
0 people found this helpful
Translate review to English
Magic, bulletproof, insanely configurable, dependable.
10 HP
Magic, bulletproof, insanely configurable, dependable. Accidentally covered ventilation intake, got so hot it melted the plastic, still runs like a champ.
0 people found this helpful
Potente
10 HP
Es silencioso y potente lo conecte aún comprensor trifásico de 5,5cv y funciona perfectamente
0 people found this helpful
Très bien
10 HP
Matériel parfait très efficace je l’utilise pour un compresseur moteur 7,5 chevaux
0 people found this helpful
S amplement satisfait
10 HP
Utilise pour pont triphasé sur une installation monophasé. Commande via le variateur de fréquence ainsi démarrage progressif possible. La notice est peu aisée à appréhender c’est un point à améliorer pour être accessible aux moins « acharnés ».
Il reste à voir dans le temps…
1 people found this helpful
Translate review to English
It works; for the most part.
10 HP
I was able to mount this to the back of my bandsaw with four screws. When it powered up, it displays a code that doesn't seem to be in the rather thick (54 page) manual. Speaking of the manual, it's mostly worthless. The default seems to by 50Hz, and it thinks the motor is spinning at 1500 RPM with the dial at 100%, idunno.
0 people found this helpful
VFD
10 HP
I'm very happy with the VFD, it powers my 3 phase 220 lathe and set up was straight forward. I height recommend it.
0 people found this helpful
Parameters for CNC spindles Got mine going!
10 HP
There is a word count limit so I am giving you the basics hope this helps mine now reads in RPM and it runs great I set up a lower limit of 12000 rpm so my air cooled spindle does not over heat.P01.10 has to be inputted first.
Auto tune is required especially for a cnc spindle(otherwise it could damage it auto tune figures out your winding resistance and specs)
My name plate Spindle settings(use your own to set up):
Max freq:300hz
Max Rpm 18000rpm
Max Current:13.5amps
Max Power 4kw
Put settings in then do auto tune then put lower frequency limit in last if needed..
Switch two wires Of UVW to change rotation if required(verify rotation when doing auto tune and verify again after because it may need changing again bug maybe).
Do not start motor until after auto tune done(auto tune requires you press run to start it though).
In totality here are the settings(mine yours may differ):
P01.10=300(Maximum output frequency 300hz in my case as on spindle name plate) )
P01.08=300(Preposition frequency 300hz in my case as on spindle name plate) )
P01.12=300(Upper Limiting Frequency 300hz in my case as on spindle name plate))
P01.01=0(Motor control mode in our case Speed Sensorless Vector Control)
P01.17=10(Acceleration time in seconds) if set too low and you will trip on current overload
P01.18=10(deceleration time in seconds) if set too low back emf will trip vfd
P02.00=1(motor type variable frequency asynchronous motor)
P02.01=4(rated power of motor 4kw in my case as on spindle name plate)
P02.02=220(rated voltage of motor 220v in my case as on spindle name plate)
P02.03=13.5(rated current of motor 13.5 amps in my case as on spindle name plate)
P02.04=300(rated frequency of motor 300hz in my case as on spindle name plate)
P02.05=18000(rated speed of motor 18000rpm in my case as on spindle name plate)
P08.03=14(led displays parameter 1in Operation status load speed display)
P08.03=14(led displays parameter 2in Operation status main frequency X display calculates rpm value for display)
After programming start an auto tune:
P02.37=2 (press enter then run button)
To set a lower frequency/rpm limit(do this only after auto tune is done it needs the full range to tune):
P01.14=200 (12000rpm/18000rpm X 300hz sets the floor at 200hz or 12000rpm)
In case you need to start over and reset to factory defaults:
P17.01=1
Leave a reply if this helps :) As for DI,Do, and PWN inputs that's going to be a you tube video..
2 people found this helpful
Mechanic
10 HP
Works fine. I was skeptical at first but this thing works. Kind of impressed me.
1 people found this helpful